4.4.3.3. BEM scheme: NAM_DATA_BEM
Fortran name | Fortran type | values | default | description | units |
NPAR_FLOOR_LAYER | integer | 1 | bumber of layers in roofs | ||
XUNIF_HC_FLOOR | real | none | heat capacity of floor layers | J m-3 K-1 | |
CFNAM_HC_FLOOR | character (LEN=28) | '' | |||
CFTYP_HC_FLOOR | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_TC_FLOOR | real | none | thermal conductivity of floor layers | W m-1 K-1 | |
CFNAM_TC_FLOOR | character (LEN=28) | '' | |||
CFTYP_TC_FLOOR | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_D_FLOOR | real | none | thickness of floor layers | m | |
CFNAM_D_FLOOR | character (LEN=28) | '' | |||
CFTYP_D_FLOOR | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_FLOOR_HEIGHT | real | none | building floor height | m | |
CFNAM_FLOOR_HEIGHT | character (LEN=28) | '' | |||
CFTYP_FLOOR_HEIGHT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_TCOOL_TARGET | real | none | |||
CFNAM_TCOOL_TARGET | character (LEN=28) | '' | cooling setpoint of indoor air | ||
CFTYP_TCOOL_TARGET | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_THEAT_TARGET | real | none | heating setpoint of indoor air | ||
CFNAM_THEAT_TARGET | character (LEN=28) | '' | |||
CFTYP_THEAT_TARGET | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_F_WASTE_CAN | real | none | fraction of waste heat into the canyon | ||
CFNAM_F_WASTE_CAN | character (LEN=28) | '' | |||
CFTYP_F_WASTE_CAN | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_EFF_HEAT | real | none | efficiency of the heating system | ||
CFNAM_EFF_HEAT | character (LEN=28) | '' | |||
CFTYP_EFF8HEAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_F_WATER_COND | real | none | fraction of evaporation for condensers | ||
CFNAM_F_WATER_COND | character (LEN=28) | '' | |||
CFTYP_F_WATER_COND | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_HR_TARGET | real | none | relative humidity setpoint | ||
CFNAM_HR_TARGET | character (LEN=28) | '' | |||
CFTYP_HR_TARGET | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_QIN | real | none | internal heat gains | W m-2 (floor) | |
CFNAM_QIN | character (LEN=28) | '' | |||
CFTYP_QIN | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_QIN_FRAD | real | none | radiant fraction of internal heat gains | ||
CFNAM_QIN_FRAD | character (LEN=28) | '' | |||
CFTYP_QIN_FRAD | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_QIN_FLAT | real | none | latent fraction of internal heat gains | ||
CFNAM_QIN_FLAT | character (LEN=28) | '' | |||
CFTYP_QIN_FLAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_SHGC | real | none | solar transmitance of windows | ||
CFNAM_SHGC | character (LEN=28) | '' | |||
CFTYP_SHGC | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_U_WIN | real | none | glazing thermal resistance | K m W-2 | |
CFNAM_U_WIN | character (LEN=28) | '' | |||
CFTYP_U_WIN | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_GR | real | none | glazing ratio | ||
CFNAM_GR | character (LEN=28) | '' | |||
CFTYP_GR | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_SHGC_SH | real | none | solar transmitance of windows + shading | ||
CFNAM_SHGC_SH | character (LEN=28) | '' | |||
CFTYP_SHGC_SH | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_INF | real | none | infiltration/ventialtion flow rate | AC/H | |
CFNAM_INF | character (LEN=28) | '' | |||
CFTYP_INF | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | v | ||
XUNIF_V_VENT | real | none | ventilation flow rate | AC/H | |
CFNAM_V_VENT | character (LEN=28) | '' | |||
CFTYP_V_VENT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_CAP_SYS_HEAT | real | none | capacity of the heating system | W m-2 (bld) | |
CFNAM_CAP_SYS_HEAT | character (LEN=28) | '' | |||
CFTYP_CAP_SYS_HEAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_CAP_SYS_RAT | real | none | rated capacity of the cooling system | W m-2 (bld) | |
CFNAM_CAP_SYS_RAT | character (LEN=28) | '' | |||
CFTYP_CAP_SYS_RAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_T_ADP | real | none | Apparatus dewpoint temperature of the cooling coil | K | |
CFNAM_T_ADP | character (LEN=28) | '' | |||
CFTYP_T_ADP | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_M_SYS_RAT | real | none | rated HVAC mass flow rate | kg s-1 m-2 (bld) | |
CFNAM_M_SYS_RAT | character (LEN=28) | '' | |||
CFTYP_M_SYS_RAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_COP_RAT | real | none | rated COP of the cooling system | ||
CFNAM_COP_RAT | character (LEN=28) | '' | |||
CFTYP_COP_RAT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_T_SIZE_MAX | real | none | |||
CFNAM_T_SIZE_MAX | character (LEN=28) | '' | |||
CFTYP_T_SIZE_MAX | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_T_SIZE_MIN | real | none | |||
CFNAM_T_SIZE_MIN | character (LEN=28) | '' | |||
CFTYP_T_SIZE_MIN | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_SHADE | real | 0 (inactivated), 1 (activated) | none | ||
CFNAM_SHADE | character (LEN=28) | flag to activate shading devices | '' | ||
CFTYP_SHADE | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' | ||
XUNIF_NATVENT | real | 0 (NONE), 1 (MANU), 2 (AUTO) | none | flag to describe bld surventilation solution | |
CFNAM_NATVENT | character (LEN=28) | '' | |||
CFTYP_NATVENT | character (LEN=6) | 'DIRECT', 'BINLLF', 'BINLLV', 'ASCLLV' | '' |