5.7.1. Namelist NAM_PREP_TEB

This namelist information is used to initialize the "TEB " urban scheme variables: road, roof and wall temperature profiles, water intercepted by roofs and roads, snow, building internal temperature.

Fortran name Fortran type values default value
XWS_ROAD real none
XWS_ROOF real none
CFILE_WS string of 28 characters CFILE_TEB in this namelist
CTYPE_WS string of 6 characters 'MESONH', 'GRIB ','LFI ' CTYPE in this namelist
XTS_ROAD real none
XTS_ROOF real none
XTS_WALL real none
XTI_BLD real none
XTI_ROAD real none
XHUI_BLD real none
CROAD_DIR character(LEN=4) 'UNIF','ORIE' 'UNIF'
CWALL_OPT character(LEN=4) 'UNIF','TWO ' 'UNIF'
CFILE_TS string of 28 characters CFILE_TEB in this namelist
CTYPE_TS string of 6 characters 'MESONH', 'GRIB ', 'LFI ' CTYPE in this namelist
CFILE_TEB string of 28 characters CFILE in NAM_PREP_SURF_ATM
CTYPE string of 6 characters 'MESONH', 'GRIB ', 'ASCII ','LFI ' CFILETYPE in NAM_PREP_SURF_ATM
CFILEPGD_TEB string of 28 characters CFILEPGD in NAM_PREP_SURF_ATM
CTYPEPGD string of 6 characters 'MESONH', 'GRIB ', 'ASCII ','LFI ' CFILEPGDTYPE in NAM_PREP_SURF_ATM
NYEAR integer none
NMONTH integer none
NDAY integer none
XTIME real none
LTEB_CANOPY logical F

  • XWS_ROAD : uniform prescribed value of soil water interception for the road reservoir. This prescribed value, if defined, has priority on the use of CFILE_WS and CFILE_TEB data.
  • XWS_ROOF : uniform prescribed value of soil water interception for the roof reservoir. This prescribed value, if defined, has priority on the use of CFILE_WS and CFILE_TEB data.
  • CFILE_WS: name of the file used to define the soil water reservoirs. The use of a file or prescribed value of XWS_ROAD and XWS_ROOF has priority on the data in CFILE_WS file.
  • CTYPE_WS: type of the CFILE_WS file, if the latter is provided. CTYPE_WS must then be given. The following values are currently usable:
    • "MESONH" : the file type is a MESONH file.
    • "GRIB " : the file type is a GRIB file, coming from any of these models:
      1. "ECMWF " : european center forecast model
      2. "ARPEGE" : Arpege french forecast model
      3. "ALADIN" : Aladin french forecast local model
      4. "MOCAGE" : Mocage french research chemistry model
  • XTS_ROAD : uniform prescribed value of temperature for road, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
  • XTS_ROOF : uniform prescribed value of temperature for roof, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
  • XTS_WALL : uniform prescribed value of temperature for wall, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
  • XTI_BLD : uniform prescribed value of internal building temperature. This temperature is not dependent on altitude. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
  • XTI_ROAD : uniform prescribed value of deep road temperature, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
  • XHUI_BLD : uniform bulding relative hum (between 0-1)
  • CROAD_DIR : TEB option for road direction:
    • UNIF : no specific direction
    • ORIE : many road ORIEntations (linked to NTEB_PATCH)
  • CWALL_OPT : TEB option for walls:
    • UNIF : uniform walls
    • TWO : two separated walls
  • CFILE_TS: name of the file used to define the soil temperature profile. The use of a file or prescribed value of XTS_ROAD, XTS_ROOF, XTS_WALL, XTI_BLD or XTI_ROAD has priority on the data in CFILE_TS file.
  • CTYPE_TS: type of the CFILE_TS file, if the latter is provided. CTYPE_TS must then be given. The following values are currently usable:
    • "MESONH" : the file type is a MESONH file.
    • "GRIB " : the file type is a GRIB file, coming from any of these models:
      1. "ECMWF " : european center forecast model
      2. "ARPEGE" : Arpege french forecast model
      3. "ALADIN" : Aladin french forecast local model
      4. "MOCAGE" : Mocage french research chemistry model
  • CFILE_TEB / CFILEPGD_TEB: name of the PREP/PGD files used to define any TEB variable. The use of a file or prescribed value XWS_ROAD, XWS_ROOF, XTS_ROAD, XTS_ROOF, XTS_WALL, XTI_BLD, XTI_ROAD, CFILE_WS or CFILE_TS has priority on the data in CFILE_TEB file.
  • CTYPE / CTYPEPGD: type of the CFILE_TEB / CFILEPGD_TEB file, if the latter is provided. CTYPE must then be given. The following values are currently usable:
    • "MESONH" : the file type is a MESONH file.
    • "GRIB " : the file type is a GRIB file, coming from any of these models:
      1. "ECMWF " : european center forecast model
      2. "ARPEGE" : Arpege french forecast model
      3. "ALADIN" : Aladin french forecast local model
      4. "MOCAGE" : Mocage french research chemistry model
    • "ASCII ": PREP/PGD Surfex ASCII file
    • "LFI ": PREP/PGD Surfex LFI file
  • NYEAR : year of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
  • NMONTH : month of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
  • NDAY : day of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
  • XTIME : time from midnight of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read). (seconds).
  • LTEB_CANOPY : activates surface boundary multi layer scheme over town.