5.7.1. Namelist NAM_PREP_TEB
This namelist information is used to initialize the "TEB " urban scheme variables: road, roof and wall temperature profiles, water intercepted by roofs and roads, snow, building internal temperature.
Fortran name | Fortran type | values | default value |
XWS_ROAD | real | none | |
XWS_ROOF | real | none | |
CFILE_WS | string of 28 characters | CFILE_TEB in this namelist | |
CTYPE_WS | string of 6 characters | 'MESONH', 'GRIB ','LFI ' | CTYPE in this namelist |
XTS_ROAD | real | none | |
XTS_ROOF | real | none | |
XTS_WALL | real | none | |
XTI_BLD | real | none | |
XTI_ROAD | real | none | |
XHUI_BLD | real | none | |
CROAD_DIR | character(LEN=4) | 'UNIF','ORIE' | 'UNIF' |
CWALL_OPT | character(LEN=4) | 'UNIF','TWO ' | 'UNIF' |
CFILE_TS | string of 28 characters | CFILE_TEB in this namelist | |
CTYPE_TS | string of 6 characters | 'MESONH', 'GRIB ', 'LFI ' | CTYPE in this namelist |
CFILE_TEB | string of 28 characters | CFILE in NAM_PREP_SURF_ATM | |
CTYPE | string of 6 characters | 'MESONH', 'GRIB ', 'ASCII ','LFI ' | CFILETYPE in NAM_PREP_SURF_ATM |
CFILEPGD_TEB | string of 28 characters | CFILEPGD in NAM_PREP_SURF_ATM | |
CTYPEPGD | string of 6 characters | 'MESONH', 'GRIB ', 'ASCII ','LFI ' | CFILEPGDTYPE in NAM_PREP_SURF_ATM |
NYEAR | integer | none | |
NMONTH | integer | none | |
NDAY | integer | none | |
XTIME | real | none | |
LTEB_CANOPY | logical | F |
- XWS_ROAD : uniform prescribed value of soil water interception for the road reservoir. This prescribed value, if defined, has priority on the use of CFILE_WS and CFILE_TEB data.
- XWS_ROOF : uniform prescribed value of soil water interception for the roof reservoir. This prescribed value, if defined, has priority on the use of CFILE_WS and CFILE_TEB data.
- CFILE_WS: name of the file used to define the soil water reservoirs. The use of a file or prescribed value of XWS_ROAD and XWS_ROOF has priority on the data in CFILE_WS file.
- CTYPE_WS: type of the CFILE_WS file, if the latter is provided. CTYPE_WS must then be given. The following values are currently usable:
- "MESONH" : the file type is a MESONH file.
- "GRIB " : the file type is a GRIB file, coming from any of these models:
- "ECMWF " : european center forecast model
- "ARPEGE" : Arpege french forecast model
- "ALADIN" : Aladin french forecast local model
- "MOCAGE" : Mocage french research chemistry model
- XTS_ROAD : uniform prescribed value of temperature for road, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
- XTS_ROOF : uniform prescribed value of temperature for roof, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
- XTS_WALL : uniform prescribed value of temperature for wall, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
- XTI_BLD : uniform prescribed value of internal building temperature. This temperature is not dependent on altitude. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
- XTI_ROAD : uniform prescribed value of deep road temperature, supposed at an altitude of 0m (mean sea level altitude). The temperature is then modified for each point depending on its altitude, following a uniform vertical gradient of -6.5 K km-1. This prescribed value, if defined, has priority on the use of CFILE_TS and CFILE_TEB data.
- XHUI_BLD : uniform bulding relative hum (between 0-1)
- CROAD_DIR : TEB option for road direction:
- UNIF : no specific direction
- ORIE : many road ORIEntations (linked to NTEB_PATCH)
- CWALL_OPT : TEB option for walls:
- UNIF : uniform walls
- TWO : two separated walls
- CFILE_TS: name of the file used to define the soil temperature profile. The use of a file or prescribed value of XTS_ROAD, XTS_ROOF, XTS_WALL, XTI_BLD or XTI_ROAD has priority on the data in CFILE_TS file.
- CTYPE_TS: type of the CFILE_TS file, if the latter is provided. CTYPE_TS must then be given. The following values are currently usable:
- "MESONH" : the file type is a MESONH file.
- "GRIB " : the file type is a GRIB file, coming from any of these models:
- "ECMWF " : european center forecast model
- "ARPEGE" : Arpege french forecast model
- "ALADIN" : Aladin french forecast local model
- "MOCAGE" : Mocage french research chemistry model
- CFILE_TEB / CFILEPGD_TEB: name of the PREP/PGD files used to define any TEB variable. The use of a file or prescribed value XWS_ROAD, XWS_ROOF, XTS_ROAD, XTS_ROOF, XTS_WALL, XTI_BLD, XTI_ROAD, CFILE_WS or CFILE_TS has priority on the data in CFILE_TEB file.
- CTYPE / CTYPEPGD: type of the CFILE_TEB / CFILEPGD_TEB file, if the latter is provided. CTYPE must then be given. The following values are currently usable:
- "MESONH" : the file type is a MESONH file.
- "GRIB " : the file type is a GRIB file, coming from any of these models:
- "ECMWF " : european center forecast model
- "ARPEGE" : Arpege french forecast model
- "ALADIN" : Aladin french forecast local model
- "MOCAGE" : Mocage french research chemistry model
- "ASCII ": PREP/PGD Surfex ASCII file
- "LFI ": PREP/PGD Surfex LFI file
- NYEAR : year of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
- NMONTH : month of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
- NDAY : day of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read).
- XTIME : time from midnight of surface UTC time. It is used only if no atmospheric file or no surface file is given (in those the date can be read). (seconds).
- LTEB_CANOPY : activates surface boundary multi layer scheme over town.