SURFEX  V8_0
Surfex V8_0 release
 All Classes Files Functions Variables
write_diag_inland_watern.F90
Go to the documentation of this file.
1 !SFX_LIC Copyright 1994-2014 CNRS, Meteo-France and Universite Paul Sabatier
2 !SFX_LIC This is part of the SURFEX software governed by the CeCILL-C licence
3 !SFX_LIC version 1. See LICENSE, CeCILL-C_V1-en.txt and CeCILL-C_V1-fr.txt
4 !SFX_LIC for details. version 1.
5 ! #########
6 SUBROUTINE write_diag_inland_water_n (DTCO, DGU, U, WM, FM, &
7  hprogram,hwrite)
8 ! ###############################################################################
9 !
10 !!**** *WRITE_DIAG_INLAND_WATER_n * - Chooses the surface schemes for lakes diagnostics
11 !!
12 !! PURPOSE
13 !! -------
14 !
15 !!** METHOD
16 !! ------
17 !!
18 !! REFERENCE
19 !! ---------
20 !!
21 !!
22 !! AUTHOR
23 !! ------
24 !! V. Masson
25 !!
26 !! MODIFICATIONS
27 !! -------------
28 !! Original 01/2004
29 !!------------------------------------------------------------------
30 !
31 USE modd_surfex_n, ONLY : flake_model_t
33 !
36 USE modd_surf_atm_n, ONLY : surf_atm_t
39 USE modd_watflux_n, ONLY : watflux_t
40 !
41 USE modd_surf_par, ONLY : xundef
42 
43 USE modi_write_diag_watflux_n
44 USE modi_write_diag_flake_n
45 !
46 !
47 USE yomhook ,ONLY : lhook, dr_hook
48 USE parkind1 ,ONLY : jprb
49 !
50 IMPLICIT NONE
51 !
52 !* 0.1 declarations of arguments
53 !
54 !
55 !
56 TYPE(data_cover_t), INTENT(INOUT) :: dtco
57 TYPE(diag_surf_atm_t), INTENT(INOUT) :: dgu
58 TYPE(surf_atm_t), INTENT(INOUT) :: u
59 TYPE(watflux_model_t), INTENT(INOUT) :: wm
60 TYPE(flake_model_t), INTENT(INOUT) :: fm
61 !
62 !
63  CHARACTER(LEN=6), INTENT(IN) :: hprogram ! program calling surf. schemes
64  CHARACTER(LEN=3), INTENT(IN) :: hwrite ! 'PGD' : only physiographic fields are written
65 REAL(KIND=JPRB) :: zhook_handle
66 ! ! 'ALL' : all fields are written
67 !
68 !
69 !* 0.2 declarations of local variables
70 !
71 !-------------------------------------------------------------------------------------
72 !
73 IF (lhook) CALL dr_hook('WRITE_DIAG_INLAND_WATER_N',0,zhook_handle)
74 IF (u%CWATER=='WATFLX') THEN
75  CALL write_diag_watflux_n(dtco, dgu, u, wm, &
76  hprogram,hwrite)
77 END IF
78 IF (u%CWATER=='FLAKE ') THEN
79  CALL write_diag_flake_n(dtco, dgu, u, fm, &
80  hprogram,hwrite)
81 END IF
82 IF (lhook) CALL dr_hook('WRITE_DIAG_INLAND_WATER_N',1,zhook_handle)
83 !
84 !-------------------------------------------------------------------------------------
85 !
86 END SUBROUTINE write_diag_inland_water_n
subroutine write_diag_inland_water_n(DTCO, DGU, U, WM, FM, HPROGRAM, HWRITE)
subroutine write_diag_watflux_n(DTCO, DGU, U, WM, HPROGRAM, HWRITE)
subroutine write_diag_flake_n(DTCO, DGU, U, FM, HPROGRAM, HWRITE)