SURFEX v8.1
General documentation of Surfex
write_diag_watfluxn.F90
Go to the documentation of this file.
1 !SFX_LIC Copyright 1994-2014 CNRS, Meteo-France and Universite Paul Sabatier
2 !SFX_LIC This is part of the SURFEX software governed by the CeCILL-C licence
3 !SFX_LIC version 1. See LICENSE, CeCILL-C_V1-en.txt and CeCILL-C_V1-fr.txt
4 !SFX_LIC for details. version 1.
5 ! #########
6 SUBROUTINE write_diag_watflux_n (DTCO, DUO, U, WM, HPROGRAM,HWRITE)
7 ! ###############################################################################
8 !
9 !!**** *WRITE_DIAG_WATFLUX_n * - diagnostics for lakes
10 !!
11 !! PURPOSE
12 !! -------
13 !
14 !!** METHOD
15 !! ------
16 !!
17 !! REFERENCE
18 !! ---------
19 !!
20 !!
21 !! AUTHOR
22 !! ------
23 !! V. Masson
24 !!
25 !! MODIFICATIONS
26 !! -------------
27 !! Original 01/2004
28 !!------------------------------------------------------------------
29 !
30 !
32 !
34 USE modd_diag_n, ONLY : diag_options_t
35 USE modd_surf_atm_n, ONLY : surf_atm_t
36 !
37 USE modd_surf_par, ONLY : xundef
38 !
39 USE modi_write_diag_seb_watflux_n
40 !
41 !
42 USE yomhook ,ONLY : lhook, dr_hook
43 USE parkind1 ,ONLY : jprb
44 !
45 IMPLICIT NONE
46 !
47 !* 0.1 declarations of arguments
48 !
49 !
50 TYPE(data_cover_t), INTENT(INOUT) :: DTCO
51 TYPE(diag_options_t), INTENT(INOUT) :: DUO
52 TYPE(surf_atm_t), INTENT(INOUT) :: U
53 TYPE(watflux_model_t), INTENT(INOUT) :: WM
54 !
55  CHARACTER(LEN=6), INTENT(IN) :: HPROGRAM ! program calling surf. schemes
56  CHARACTER(LEN=3), INTENT(IN) :: HWRITE ! 'PGD' : only physiographic fields are written
57 REAL(KIND=JPRB) :: ZHOOK_HANDLE
58 ! ! 'ALL' : all fields are written
59 !
60 !* 0.2 declarations of local variables
61 !
62 !-------------------------------------------------------------------------------------
63 !
64 IF (lhook) CALL dr_hook('WRITE_DIAG_WATFLUX_N',0,zhook_handle)
65 IF (hwrite/='PGD') THEN
66 !
67  IF (wm%DWO%XDIAG_TSTEP==xundef .OR. &
68  abs(nint(wm%W%TTIME%TIME/wm%DWO%XDIAG_TSTEP)*wm%DWO%XDIAG_TSTEP-wm%W%TTIME%TIME)<1.e-3 ) THEN
69  CALL write_diag_seb_watflux_n(dtco, duo, u, wm%CHW, wm%DWO, wm%DW, wm%DWC, hprogram)
70  END IF
71 !
72 ENDIF
73 IF (lhook) CALL dr_hook('WRITE_DIAG_WATFLUX_N',1,zhook_handle)
74 !-------------------------------------------------------------------------------------
75 !
76 END SUBROUTINE write_diag_watflux_n
subroutine write_diag_seb_watflux_n(DTCO, DUO, U, CHW, DWO, D, DC
real, parameter xundef
subroutine write_diag_watflux_n(DTCO, DUO, U, WM, HPROGRAM, HWRITE)
integer, parameter jprb
Definition: parkind1.F90:32
logical lhook
Definition: yomhook.F90:15